NIST - National Institute of Standards and Technology

01/10/2025 | Press release | Archived content

Commutability Assessment of New Standard Reference Materials (SRMs) for Determining Serum Total 25 Hydroxyvitamin D using Ligand Binding and Liquid Chromatography – Tandem Mass[...]

Published
January 10, 2025

Author(s)

Stephen Wise, Etienne Cavalier, Pierre LUKAS, Stephanie Peeters, caroline Le Goff, Laura Briggs, Emma Williams, Ekaterina Mineva, Christine Pfeiffer, Hubert Vesper, Christian Popp, Christian Beckert, Jan Schultess, Kevin Wang, Carole Tourneur, Camille Pease, Dominik Osterritter, Ralf Fischer, Ben Saida, Chao Dou, Satoshi Kojima, Hope Weiler, Agnieszka Bielecki, Heather Pham, Alexandra Bennett, Shawn You, Amit Ghoshal, Chistian Vogl, James Freeman, Neil Parker, Samantha Pagliaro, Jennifer Cheek, Jie Li, Hisao Tsukamoto, Karen Galvin, Kevin Cashman, Hsuan-Chieh Liao, Andrew Norbert Hoofnagle, Jeffery Budd, Adam Kuszak, Ashley Boggs-Russell, Carolyn Burdette, Grace Hahm, Federica Nalin, Johanna Camara

Abstract

Commutability is where the measurement response for a reference material (RM) is the same as for an individual patient sample with the same concentration of analyte measured using two or more measurement systems. Assessment of commutability is essential when the RM is used in a calibration hierarchy or to ensure that clinical measurements are comparable across different measurement procedures and at different times. The commutability of three new Standard Reference Materials® (SRMs) for determining serum total 25-hydroxyvitamin D [25(OH)D], defined as the sum of 25-hydroxyvitamin D2 [25(OH)D2] and 25-hydroxyvitamin D3 [25(OH)D3], was assessed through an interlaboratory study. The following SRMs were assessed: (1) SRM 2969 Vitamin D Metabolites in Frozen Human Serum (Total 25-Hydroxyvitamin D Low Level), (2) SRM 2970 Vitamin D Metabolites in Frozen Human Serum (25-Hydroxyvitamin D2 High Level), and (3) SRM 1949 Frozen Human Prenatal Serum. These SRMs represent three clinically relevant situations including (1) low levels of total 25(OH)D, (2) high level of 25(OH)D2, and (3) 25(OH)D levels in nonpregnant women and women during each of the three trimesters of pregnancy with changing concentrations of vitamin D-binding protein (VDBP). Twelve laboratories using 17 different ligand binding assays and eight laboratories using nine commercial and custom liquid chromatography-tandem mass spectrometry (LC-MS/MS) assays provided results in this study. Commutability of the SRMs with patient samples was assessed using the Clinical and Laboratory Standards Institute (CLSI) approach based on 95% prediction intervals or a pre-set commutability criterion and the recently introduced International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) approach based on differences in bias for the clinical and reference material samples using a commutability criterion of 8.8%. All three SRMs were deemed as commutable with all LC-MS/MS assays using both CLSI and IFCC approaches. SRM 2969 and SRM 2970 were deemed noncommutable for three and seven different ligand binding assays, respectively, when using the IFCC approach. Except for two assays, one or more of the three pregnancy levels of SRM 1949 were deemed noncommutable or inconclusive using different ligand binding assays and the commutability criterion of 8.8%. Overall, a noncommutable assessment for ligand binding assays is determined for these SRMs primarily due to a lack of assay selectivity related to 25(OH)D2 or an increasing VDBP in pregnancy trimester materials rather than the quality of the SRMs. With results from 17 different ligand binding and nine LC-MS/MS assays, this study provides valuable knowledge for clinical laboratories to inform SRM selection when assessing 25(OH)D status in patient populations, particularly in subpopulations with low levels of 25(OH)D, high levels of 25(OH)D2, women only, or women who are pregnant.
Citation
Analytical and Bioanalytical Chemistry
Pub Type
Journals

Keywords

25-Hydroxyvitamin D2, 25-Hydroxyvitamin D3, Immunoassay, Reference measurement procedure (RMP), Vitamin D, Vitamin D-binding protein (VDBP)

Citation

Wise, S. , Cavalier, E. , Lukas, P. , Peeters, S. , Le Goff, C. , Briggs, L. , Williams, E. , Mineva, E. , Pfeiffer, C. , Vesper, H. , Popp, C. , Beckert, C. , Schultess, J. , Wang, K. , Tourneur, C. , Pease, C. , Osterritter, D. , Fischer, R. , Saida, B. , Dou, C. , Kojima, S. , Weiler, H. , Bielecki, A. , Pham, H. , Bennett, A. , You, S. , Ghoshal, A. , Vogl, C. , Freeman, J. , Parker, N. , Pagliaro, S. , Cheek, J. , Li, J. , Tsukamoto, H. , Galvin, K. , Cashman, K. , Liao, H. , Hoofnagle, A. , Budd, J. , Kuszak, A. , Boggs-Russell, A. , Burdette, C. , Hahm, G. , Nalin, F. and Camara, J. (2025), Commutability Assessment of New Standard Reference Materials (SRMs) for Determining Serum Total 25-Hydroxyvitamin D using Ligand Binding and Liquid Chromatography - Tandem Mass Spectrometry (LC-MS/MS) Assays, Analytical and Bioanalytical Chemistry, [online], https://doi.org/10.1007/s00216-024-05699-7, https://tsapps.nist.gov/publication/get_pdf.cfm?pub_id=957819 (Accessed January 14, 2025)

Additional citation formats

Issues

If you have any questions about this publication or are having problems accessing it, please contact [email protected].